Pick up an ultrabook halfway through a 4K export or a batch of local inference. The aluminum underside is lukewarm, a tiny blower whispers at several thousand RPM, and somewhere inside, a postage-stamp-sized sliver of silicon is dumping 36 watts into a chassis barely twelve millimeters thick.
And yet that heat escapes an enclosure thin enough to slide into the yellow manila envelope Steve Jobs famously emptied on stage in 2008, all while the aluminum chassis stays comfortable to the touch.
Ask an electronic engineer about heat and they will talk primarily about efficiency: conduction losses in copper, gate-drive and switching losses in a MOSFET, and hysteresis in an inductor core. An EE’s primary instinct is prevention: tuning topologies and choosing components so less heat is generated in the first place.
But thermodynamics always takes its toll. Once electrical energy turns into thermal energy, circuit design gives way to thermal and mechanical engineering. If you are reading this, it might be your turn.
In mechanical engineering circles, thermal management is mostly explained as a set of steady-state problems. You might learn how heat diffuses smoothly along a copper pipe, or how to calculate a surface temperature under a constant thermal load and steady-state conditions. You’re far less likely to learn about modern thermal interface materials, or about the dynamic, pulsed and unpredictable heat sources found in modern electronics.
This article aims to fill that gap: an introduction to advanced thermal engineering for electronic devices.
Before choosing any heat sink, fan, heatpipe or thermal interface material, you must answer three fundamental questions about your system. Together, they should sufficiently constrain the problem:
The heat source is perhaps the most important component in the whole thermal path.
Apple learned this the hard way. In 2016 it introduced a thinner MacBook Pro, and in July 2018 it fitted the 15-inch model with Intel’s six-core Core i9-8950HK, rated at 45 W and boosting to 4.8 GHz. Under a long video export, the chip could not even hold its 2.9 GHz base clock, and in a benchmark loop it hit its 100 °C limit, making the system extremely sluggish. Apple blamed a firmware bug and patched it within a week, but even afterwards Notebookcheck measured the chip drawing about 90 W at first, then settling at 47–52 W, about all the cooling could handle. In a sustained benchmark the i9 ended up slower than the cheaper i7. The 16-inch model that replaced it in 2019 got a 35% larger heat sink.
Heat sources behave wildly differently. Industrial systems often have constant or slowly cycling loads, which are at least somewhat predictable and can usually be modeled. Computers and smartphones produce short bursts of heat whenever the workload changes unpredictably, for example when the user opens an app or plugs in the charger.
To design an effective system, you need to understand a few fundamental things about the source.
Identify the dissipated power both in the worst-case scenario and in an average situation, and consider the losses throughout the entire system. A small industrial power supply that draws 100 W at 90% efficiency, for example, dissipates 10 W as heat.
What matters, engineering-wise, is the heat flux, the power per unit area. The die of a modern laptop processor might measure about 18 × 12 mm (0.71 × 0.47 in), or 2.16 cm² (0.33 in²). If it dissipates 36 W, its heat flux is:

Our 10 W power supply, by contrast, spreads its heat over a board of about 100 × 200 mm (3.9 × 7.9 in), or 200 cm² (31 in²):

Those two numbers differ by a factor of over 300, which can be hard to fathom.
A great way to picture them is to scale them up to the desk in front of you. A standard desk is about 70 cm by 1.4 m (28 × 55 in). Heat it at the same density as the power supply, and it gives off 490 W, about half the midsummer noon sun in Sacramento, California. Apply the density of a modern laptop processor instead, and it gives off 163 kW, more than 160 times the midsummer noon sun.
The high peak flux means that the first few millimeters of the heat path are the most critical. Close to a processor die, the heat has to be removed immediately and as efficiently as possible. That’s why gaming PC builders obsess over the quality of their thermal paste.
This is the question that often gets skipped, and yet it is what separates a mediocre, unreliable product from a great one. Some equipment produces heat at a fairly steady rate for long periods. Industrial electronics are a good example: there may be room for a substantial heat sink, and the brief may favour reliability, low cost and simple construction over minimum size and mass. The job is to move heat away continuously and keep temperatures in a comfortable range.
Other equipment sees an uneven load. The laptop from the introduction spends long stretches at low power, then produces a burst of heat when a render or a local AI model starts. The design must keep the temperature rise in check quickly enough to preserve performance. If the processor reaches its thermal limit, it throttles: it reduces its operating frequency, and the device feels sluggish.

Thermal profiles over time: continuous industrial load versus bursty processor load Continuous versus pulsed thermal loads. Top: a steady industrial load over hours. Bottom: an ultrabook processor idling near 5 W, with bursts up to 64 W. Illustrative, not measured data.
Every chip has a maximum junction temperature (Tj,max), the hottest its transistors are allowed to get: 100 °C for the i9 above, and often 125–175 °C for other chips and power transistors. Beyond it, the maker no longer guarantees that the part will work, or for how long. But long before a chip shuts down, heat slowly undermines its reliability. Heat makes atoms jiggle, and with enough jiggling some of them move for good. In the thin copper wires on a chip, the flowing electrons push the metal atoms along, a process called electromigration, which slowly opens voids in some places and piles up metal in others, until a line breaks or shorts to its neighbor. In the solder joints between a PCB and its components, brittle intermetallic layers grow at the interface, and every heat-up and cool-down cycle spreads cracks through the joint.
Something to be aware of: the thermal behavior of a part can change during its life cycle, even though its electrical parameters stay the same. China’s packaging industry has grown enormously in the past few years, and it had nearly 200 assembly and test plants, and in 2024 mainland China hosted about 28% of the world’s chip assembly, packaging and test capacity. Many chip makers now package and test their parts there, including Intel and Onsemi, and while packaging changes generally do not affect a part electrically, they can radically change its thermal properties. These changes are often announced in product change notices, but they are easy to miss, so always check the manufacturer’s current datasheet, for example from the part’s page on Octopart.
Many of these mechanisms follow the Arrhenius law: as a rule of thumb, for a typical activation energy of about 0.7 eV, every sustained 10 K rise in junction temperature roughly doubles their failure rate. Fatigue cracks in solder are the exception; they depend on how often, and by how much, the temperature swings.
Throttling, i.e. dynamically reducing the thermal load when temperatures get too high, can serve as an emergency safety net or as the core operating strategy of your product’s thermal management. In modern laptops and smartphones, processors are deliberately allowed to draw well above their continuous cooling budget, called thermal design power (TDP), for seconds to tens of seconds (Intel recommends averaging over about 28 seconds), burning through their thermal reserves to deliver snappy responses, then dialling back before the chassis overheats.
The difficult part is that throttling is an interaction design problem and a user experience problem as much as a thermal one. On your phone, a sudden clock-speed reduction that drops video frames during playback or causes audio stutter makes the device seem faulty, whereas the same slowdown during a three-hour background task goes unnoticed. Designing for throttling requires deciding what degree of performance determinism your user expects, keeping in mind that user experience can often be traded off against reliability, through the aforementioned Arrhenius relationship.
Two of the most popular safety standards used in the industry for surface touch temperatures are IEC 62368-1, for consumer and IT equipment, and IEC 60601-1, for medical devices. Both set their limits based on the material of the surface and the amount of time the user can be expected to touch it.
For medical electrical equipment, IEC 60601-1 sets the following limits:
Contact time | Metal | Glass/ceramic | Plastic/wood |
Under 1 s | 74 °C | 80 °C | 86 °C |
1–10 s | 56 °C | 66 °C | 71 °C |
10 s – 1 min | 51 °C | 56 °C | 60 °C |
1 min or more | 48 °C | 48 °C | 48 °C |
Consumer and IT equipment falls under IEC 62368-1, which uses a similar scheme:
Contact time | Metal | Glass/ceramic | Plastic |
Under 1 s | 70 °C | 80 °C | 94 °C |
1–10 s | 60 °C | 71 °C | 77 °C |
10 s – 1 min | 51 °C | 56 °C | 60 °C |
1 min – 8 h | 48 °C | 48 °C | 48 °C |
Over 8 h, worn on the body | 43–48 °C | 43–48 °C | 43–48 °C |
While regulations are useful to guarantee that your product won’t harm your users, they won’t save you from user complaints. Temperatures well below the safety limits may still feel uncomfortable, and translating the subjective perception of heat into an objective, replicable engineering requirement is notoriously difficult. However, human perception studies have provided some useful ranges:
Both aluminum and copper are excellent at conducting and spreading heat, but by any measure, neither of them is that impressive at storing it.
Material | cp (J/(kg·K)) | Density (kg/m³) | Volumetric heat capacity (MJ/(m³·K)) |
Aluminum | 900 | 2,700 | 2.4 |
Copper | 387 | 8,920 | 3.5 |
Water | 4,186 | 1,000 | 4.2 |
The specific heat capacity (cp) indicates how much energy a kilogram of material can absorb per kelvin of temperature rise. A kilogram of water stores about 4.7 times as much heat as aluminum and 10.8 times as much as copper.
Heat capacity is one of the fundamental reasons life on Earth is so comfortable. Oceans cover 70% of the planet, and their top 3 m (10 ft) alone store more heat than the entire atmosphere, so they soak up the summer and give it back in winter.
The most important parameter for a physical part is the total heat capacity, in J/K, which you can get by multiplying the specific heat capacity by the mass:

For example, a 50 g aluminum spreader holds about 45 J per kelvin. Heated with a steady 15 W from room temperature, it will take only 54 seconds to become hot to the touch (from 25 °C to 43 °C).
Pyrolytic graphite sheet (PGS) is a thin film of highly oriented graphite, often used to spread heat across a phone or laptop chassis. PGS’s conductivity depends strongly on the orientation of the graphite layers. In the X–Y plane, it can conduct nearly five times better than copper (up to 1,950 W/(m·K)); through its thickness (Z) it is a poor conductor, as low as 3.4 W/(m·K). This incredible property is called orthotropic thermal conductivity, and it makes PGS brilliant at taking a concentrated hot spot and spreading it across a larger area.
When selecting pyrolytic graphite, you should make sure to check the datasheet for exact grades and constructions. Some products are bare graphite. Others are laminated with PET or polyimide film and adhesive. Panasonic alone sells PGS under dozens of EYG-S part numbers, one per size, thickness and laminate; searching the prefix on Octopart lists them all, with datasheets.
Product | Country | Thickness | In-plane (W/(m·K)) | Through-plane (W/(m·K)) | Stated method |
Japan | 10–100 µm | 700–1,950 | Not stated | Not stated | |
US | 17–50 µm | 1,350–1,600 | 3.4 | In-house; ASTM D5470 modified | |
China | 17 µm | ≥1,500 | 5–10 | Thermal wave | |
Taiwan | 25 µm | 1,500 | 5 | Angstrom; ASTM D5470-06 | |
China | 25 µm | 1,500 | 15 | Laser flash, both axes | |
China | 22–27 µm | 1,350–1,650 | 8 | XY: ASTM E1461; Z: ASTM D5470 | |
China | 25 µm | 1,500–1,700 | 10–15 | Not stated |
The most common family of thermal interface materials consists of a silicone matrix loaded with thermally conductive particles, usually ceramics such as alumina or boron nitride. Depending on the viscosity, the result is either a thermal paste or a thermal pad. Think of it like mayonnaise, an emulsion: the particles are separated by the matrix, and just like mayonnaise, if it’s poorly made, it can separate.
Anyone doing thermal engineering has at some point asked themselves: are TIMs really needed? They’re sometimes gross, goopy, and just another line in the BOM that requires you to draft a standard operating procedure (SOP) on how to apply them.
The answer is yes: thermal interface materials are almost always necessary.
Put a straightedge on a freshly machined aluminum plate and it may look flat. But can you feel the texture with the ridges of your fingerprints? And how planar is it really? As any good mechanical engineer knows, flatness is just a measure of how much surface imperfection we are willing to tolerate.
Where heat transfer is concerned, any machined surface is hopelessly imperfect. Two surfaces may offer enough contact area for them to transfer a mechanical force effectively, but at a microscopic level, for heat to be transferred, the atoms have to be close enough to wiggle together.
Thermal interface materials fill the gaps between imperfect surfaces, where only 1–2% of the area actually touches.

Dry contact versus compressed TIM for rough, machined and bowed faces (a) surface roughness, (b) ridges left by a slightly tilted flat end mill on both faces, (c) faces dished away from each other. Left: dry contact. Right: properly compressed TIM. Not to scale.
Every component in a thermal pad formulation has a precise role:
Pads are quite straightforward to use and understand, and that’s perhaps why they are so popular. But if there is one common mistake to watch out for, it’s confusing the test methods used to specify a pad’s performance.
The two most common methods are ASTM D5470, which clamps a sample between meter bars, and the hot-disk method (ISO 22007-2), which measures the bulk material with a heated sensor.

ASTM D5470: a sample clamped between two instrumented metal bars, heater above and cold plate below, with the temperature profile through the stack; hot disk: a thin spiral sensor sandwiched between two pieces of sample, with its temperature rise over time (a) ASTM D5470 drives steady heat through a sample and measures the temperature drop across the entire length, including contact resistance. (b) The hot disk heats a thin sensor between two pieces of sample and reads its temperature rise over a few seconds.
There is no direct way to convert between them, and the gap, pun intended, can be large:
Product | Form | ASTM D5470 (W/(m·K)) | Hot disk (W/(m·K)) |
Pad | 17 | 11 | |
Gel pad | 20 | 12 |
Before comparing two datasheets, check that they use the same method, the same thickness and the same clamping pressure.
Watch the small print too: t-Global, for example, rates its TG-A9000 pads at 9.0 W/(m·K) by a modified ASTM D5470.
Reliability is manufacturer- and formulation-specific as well. Depending on the product, the failure modes to ask about include oil bleed, slumping on vertical surfaces, hardening, and drying out. For demanding applications, get the exact material’s test data and validate it at your actual temperature, pressure, orientation and service life. That data is often proprietary, and might only be available under NDA.
Thermal paste, or thermal grease, is ideal for surfaces that already fit closely and whose flatness can be tightly controlled, such as a CPU lid and its cooler, where it squeezes down to a thin layer only a few tens of micrometers thick. The thickness matters: the thinner the layer, the lower the thermal resistance.
Shin-Etsu, the Japanese silicone maker, is a great example, and one of the laptop industry’s worst-kept secrets. One of its most popular pastes, X-23-7921-5, is rated at 6.0 W/(m·K), modest next to the pads discussed earlier, but it squeezes down to a minuscule 25 µm bond line.
The thinness of the bond line is why thermal paste performs so well. The thermal resistance of a layer is its thickness t divided by its conductivity k and its area A:

Take the 18 × 12 mm die from earlier, dissipating 36 W, and two materials with the same 6 W/(m·K) rating: a 0.5 mm pad and a 25 µm layer of paste. The pad comes out at 0.39 K/W, so the die runs about 14 K hotter than the cooler above it. The paste comes out at 0.019 K/W, a drop of just 0.7 K.
Datasheets for even the most basic pastes reflect this. Wakefield’s zinc-oxide 120-SA is rated at only 0.735 W/(m·K), but at 25 µm over a square inch its thermal resistance is just 0.05 K/W.
When even the best thermal paste becomes a bottleneck, metallic interfaces are the last resort. For years they stayed inside high-tech semiconductor packages. Now device manufacturers are adopting them for high-end consumer applications too. ASUS hand-applied liquid metal in its ROG Mothership gaming laptop in 2019, built a patented machine to apply it in 2020, and by 2021 was using it in every ROG laptop. Sony uses it in the PlayStation 5.
They fall into two main categories:
At some point, many advanced designs using only heat conduction run out of road.
A copper rod 10 mm in diameter carrying 30 W can only be about 105 mm long before one end gets to 125 °C while the other stays at a comfortable 25 °C.
Even natural single-crystal diamond, the best natural bulk thermal conductor, only stretches that to about half a meter.
When you’re thinking of using silver instead of copper, have squeezed the thermal paste down to twenty micrometers, and laid down synthetic graphite to smear out every hot spot, yet your design somehow weighs two kilograms more than it should, it’s a sign you need to change the fundamental physics of how you’re moving the heat around. When solid conduction fails, you have to stop diffusing heat atom-by-atom and start physically transporting it through a moving fluid.
The secret behind the way a heatpipe works is water’s astronomical latent heat of vaporisation.
Warming a gram of liquid water by one kelvin absorbs 4.2 joules of heat. Evaporate that same gram of water at 60 °C under partial vacuum, and it swallows 2,360 joules without warming by even a fraction of a degree. To carry 30 W away from a processor die, a heatpipe needs to boil off only 13 milligrams of water per second, or roughly 46 grams an hour.
Stripped of supplier mystique, a heatpipe is essentially a pump with no moving parts. It works in a closed loop.

A heatpipe in section: heat enters the evaporator, vapor flows along the core, condenses at the condenser, and the liquid returns through the wick
The loop runs in four steps:
The trick of using capillary action and surface tension as a motorless pump sat dormant for two decades after Richard Gaugler first patented a wicked tube for General Motors refrigerators in 1942. It took the nuclear space race to bring it to the forefront of engineering. In 1963, George Grover at Los Alamos National Laboratory, designing power reactors for orbital satellites, independently reinvented the device and named it the “heatpipe”; his team built the first prototypes using water and liquid sodium.
By 1968, a heatpipe was controlling temperatures on GEOS-II, a NASA satellite in orbit; in the 1970s, over 100,000 passive thermosiphons, wickless heatpipes that return their liquid by gravity, were installed to keep the permafrost frozen along the Trans-Alaska Pipeline. Yet heatpipes did not become everyday consumer items until the mid-1990s, when scorching Intel Pentium processors arrived in thin laptop chassis.
The wick dictates how much power the heatpipe can carry and how much tilt it can tolerate.
Two fundamental numbers describe a wick. The first is the effective pore radius, reff: the smaller the pores, the harder the wick pulls. Set that suction against gravity and you get the height to which a wick can lift water:

The second is permeability, K, measured in m², which says how easily liquid seeps through the wick. Pushing a mass flow m of liquid with viscosity along a wick of length L and cross-section A costs:

Commercially available designs use four main construction methods:
The physics presents a fundamental trade-off, which is well illustrated in this table from the NASA Heat Pipe Design Handbook:
Wick | Effective pore radius | Permeability (10−10 m2) | Static water lift at zero flow |
Axial grooves | 0.25–1.5 mm | 35–1,250 | 8–50 mm |
100-mesh screen | 0.12 mm | 1.8 | 104 mm |
200-mesh screen | 0.063 mm | 0.55 | 197 mm |
Sintered powder | 0.01–0.1 mm | 0.1–10 | 125–1,250 mm |
Put simply: the smaller the pores, the higher the wick can hold water up against gravity: from a few centimeters for grooves to over a meter for the finest sintered powder. But the same small pores make the wick far less permeable, so the liquid struggles to flow back.
So no wick is necessarily “the best”: suction grows as 1/reff, while permeability shrinks as r2eff.

Capillary suction falls as 1/r while flow through the wick rises as r², so small pores pull hard but let little liquid through Shrinking the pores strengthens the pull but chokes the flow.
Making a sintered wick is less exotic than it may sound. A solid rod, called a mandrel, is inserted into a copper tube. Copper powder is vibrated into the remaining gap, and the assembly is baked at 800–1,000 °C in a hydrogen-rich atmosphere, which keeps the copper free of oxide. That is below copper’s melting point of 1,085 °C, but hot enough that where the grains touch, they grow a small metal neck, and the powder fuses into a rigid sponge that is roughly half empty space. Finally, the mandrel is pulled out, and the tube is evacuated, charged with a measured dose of degassed water and crimped shut.

Five steps of making a sintered wick: insert the mandrel, vibrate in copper powder, bake in a hydrogen furnace, pull out the mandrel, then evacuate, add water and crimp shut Making a sintered copper wick. Not to scale.
If you want to try the different wicks for yourself, Advanced Thermal Solutions (ATS), a popular American manufacturer of standard heatpipes, is a great place to start: you can evaluate the differences on the bench without committing to any tooling costs. ATS even spells the wick out in its part numbers, S for sintered and G for grooved, so you can simply search for the ATS-HP-D6 prefix on Octopart to see the sintered and grooved 6 mm pipes side by side, with distributor stock.
The wick’s biggest enemy is gravity. When a device sits flat on a desk and its heatpipe lies horizontal, the capillary suction only has to fight fluid friction. But tilt a laptop on its side or hold a phone upside down, and the evaporator may sit higher than the condenser.
Lifting water against gravity imposes a hydrostatic penalty:


Heatpipe orientation: evaporator below, level with and above the condenser. Orientation and liquid return. With the evaporator above the condenser (c), the wick must also lift the liquid by h, so the pipe can carry far less heat.
Take a 150 mm heatpipe with three different wicks. Gravity requires about 960 Pa for every 100 mm the water has to climb, at 60 °C. Here is the effect on each type of wick:
With the pipe lying flat, where gravity costs nothing, a coarse wick can carry as much heat as a sintered one, or even more, because the liquid flows back so easily. Tilt the pipe against gravity and the fine pores win. That is why sintered powder is the default in laptops and phones, which get used at every angle.

Rated maximum heat load against tilt for 6 mm and 8 mm sintered heatpipes, falling from evaporator below to evaporator above Rated maximum heat load against tilt for standard sintered heatpipes (Celsia).
When testing heatpipes, there are a couple of important rules to follow:
In the dryout state, a heatpipe will need far more time to recover, and the heat has to be reduced enough that the hotspot can refill with fluid through capillary action.
While a heatpipe moves heat along a line, a vapor chamber is effectively a flat, two-dimensional heatpipe.
The physics works just the same, but the wide surface area of the vapor chamber brings some key advantages. While a heatpipe is amazing at moving heat, eventually the heat has to be spread using either a large aluminum block or the graphite sheets we discussed previously. A vapor chamber, however, can also spread the heat over a large surface.
Additionally, the flat shape is particularly convenient for interfacing with silicon dies and other electronic component packages, removing the need for large copper blocks. Vapor chambers also often cope better than heatpipes when the evaporator ends up above the condenser, partly because the liquid has a shorter path back to the hot spot.
Vapor chambers used to be a premium part, found mostly in gaming laptops and graphics cards. They are now cheap enough to go into phones: Apple added one to the iPhone 17 Pro in September 2025, laser-welded into the aluminum frame. Competition from Chinese suppliers has helped. One market report puts the average price of a standard chamber at about $4.50 in 2025.
For a bench test, standard chambers are also easy to buy in single units, such as t-Global’s 56 × 56 × 3 mm TGVC-56-56-3.0-01, though expect a single-unit price well above that average.
Vapor chambers, however, come with some disadvantages. Flat walls resist internal pressure far less well than a tube: Celsia rates unreinforced chambers to about 110 °C before they start to deform, against about 200 °C for an equivalent heatpipe. Vapor chambers also cost more, and they come flat, or at most bent into an L or a U shape.
Suppliers now quote chambers as thin as 0.2–0.25 mm for phones, but as always, the thinner the heatpipe or vapor chamber, the less material and liquid there is behind the evaporator, increasing the risk of dryout.
Thermal engineering can feel a bit like abstract art. There is hardly ever a single right answer, and that leaves an enormous amount of room for creativity. Perhaps it should be called thermal transfer engineering, as it’s all about how you move the heat around, and that can change everything about your product: how it behaves under load, its weight, shape and size, even its looks.
If you are willing to embrace the latest technologies, like synthetic graphite sheets, liquid metal or a properly designed vapor chamber, you can gain a real competitive advantage over teams still bolting CNC-machined aluminum on at the end.
Whichever path you take, a thermal design will likely be made up of a number of standard off-the-shelf parts, such as pads and thermal paste. To make your life as easy as possible, keep track of every thermal component like any other line in your BOM using the Octopart BOM Tool. Part pages also show how many distributors stock each part. A part listed by only one, like the t-Global vapor chamber above, is a single-source risk to check before you design it in.
The CPU can draw well above its cooling budget for up to a few tens of seconds, but then it must dial back before the chassis overheats. If it gets too hot, it has no option but to slow down.
Limits vary by chip: the i9 above tops out at 100 °C, and many other parts allow 125 °C or more. However, that doesn’t mean it’s a good idea to keep them at their limit for a long time: every sustained 10 K below it roughly halves the failure rate.
The safety limit depends on the material of the surface and on how long people are expected to touch it. For a metal surface users are expected to keep touching, IEC 62368-1 allows up to 48 °C. However, in research, 42 °C already felt hot and slightly uncomfortable.
Yes, almost always. Even precision-machined surfaces are never perfectly flat, and only 1–2% of the area actually touches and transfers heat between the parts. Paste, pads or other thermal interface materials fill these gaps, ensuring effective heat transfer.
It depends. Thermal paste can squeeze incredibly thin, ensuring a minimal temperature drop across it. However, if their performance is good enough, thermal pads are often more convenient to use and install.
Liquid metal thermal interface materials are incredibly high-performance. However, they need special mechanical features to keep them in place, and they can damage aluminum parts. Metal foil can be a better choice in many applications.
A vapor chamber is effectively a flat heatpipe. While a heatpipe moves heat along a line, a vapor chamber spreads it over a surface. Vapor chambers are a newer technology but, used correctly, they can solve many challenges that used to require multiple parts.
It depends on your application, but in many cases, particularly in consumer electronics, it will probably be a heatpipe with a sintered copper powder wick. However, if your product is installed in a fixed position and needs to dissipate a lot of heat, you might consider grooved heatpipes or even thermosiphons.