Time Mark 660

This Trip Control unit is designed to monitor and maintain a set level on a measurable variable, such as liquid...
数据表

价格与库存

DistributorSKUMinPkg
Electronic Supply6606
5d

数据表和文档

下载 Time Mark 660 的数据表和制造商文档。

Time Mark

Datasheet2 页14 年前

供应链

Country of OriginUSA

描述

由其分销商提供的 Time Mark 660 的描述。

This Trip Control unit is designed to monitor and maintain a set level on a measurable variable, such as liquid level, temperature, pressure, flow, etc. A user-provided 4-20mA current loop represents the measurable application. Two trip points, the rising setpoint, and the falling setpoint are field adjustable. They are set by calibrating the DEAD BAND and TRIP adjustments. If the input is between the two setpoints, the relays are de-energized. If the input goes above the rising setpoint, the RISING TRIP relay energizes to provide a tripped condition. This tripped condition willautomatically reset when the input falls back below the setpoint. If the input falls below the falling setpoint the FALLING TRIP relay energizes to provide a tripped condition. The tripped condition resets when the input rises back above the setpoint. It has top-mounted LEDs for status indication. Individual RISING TRIP or FALLING TRIP LEDs turn ON in a tripped condition. The INPUT LOOP ERROR LED turns ON if the input is outside the 4-20mA range. A Time Mark Model 650 Loop Power Supply (or equivalent) is required to provide DC operating voltage. A Time Mark Model 672-15 Pressure Transducer (or equivalent) is required to provide the input signal.