Honeywell AWM5103VN

Flow Sensor Measuring range: 0...15 SLPM Operating temperature: -20...70 °C Operating voltage: 8...15 VDC
$ 237.16
Production

数据表和文档

下载 Honeywell AWM5103VN 的数据表和制造商文档。

IHS

Datasheet4 页27 年前

Honeywell

Arrow Electronics

TME

Sager Electronics

库存历史记录

3 个月趋势:
+468%

供应链

Lifecycle StatusProduction (Last Updated: 4 months ago)

描述

由其分销商提供的 Honeywell AWM5103VN 的描述。

Flow Sensor Measuring range: 0...15 SLPM Operating temperature: -20...70 °C Operating voltage: 8...15 VDC
SENSOR, MASS AIR FLOW, 15L/MIN; Pressure, Max:50psi; Voltage, Supply DC Max:15V; Max Flow Rate:15l/min; Range, Measuring:0 to 15 litres/min; External Depth:35mm; External Length / Height:163mm; Fixing Centres LxW:43.2 x 20.3; Hysteresis:± 0.5% of reading; Series:AWM5000; Supply Voltage:10V dc; Temp, Op. Max:85°C; Temp, Op. Min:-25°C; Time, Response:60ms; Voltage, Output:5V; Width, External:32mm
In-Line Flow MeasurementAWM5000 Series Microbridge Mass Airflow Sensors feature a Venturi type flow housing. They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25" H2
AWM5000 Series airflow sensor, amplified, flow/pressure range: 0 SLPM to 15.0 SLPM; threaded port style, ¼ NPT In-Line Flow Measurement AWM5000 Series Microbridge Mass Airflow Sensors feature a Venturi type flow housing. They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25" H2O. The microbridge chip is in direct contact with the flow stream, greatly reducing error possibilities due to orifice or bypass channel clogging. Rugged, Versatile Package The rugged plastic package has been designed to withstand common mode pressures up to 50 psi, and the small sensing element allows 100 g of shock without compromising performance. The included "AMP" compatible connector provides reliable connection in demanding applications. On-board Signal Conditioning Each AWM5000 sensor contains circuitry which performs amplification, linearization, temperature compensation, and gas calibration. A 1 to 5 Vdc linear output is possible for all listings regardless of flow range (5, 10, 15, or 20 SLPM) or calibration gas (nitrogen, carbon dioxide, nitrous oxide, or argon). All calibration is performed by active laser CAUTION PRODUCT DAMAGE AWM Series Microbridge Mass Airflow Sensors are not designed to sense liquid flow and will be damaged by liquid flow through the sensor. Failure to comply with these instructions could result in product damage.

制造商别名

Honeywell 在全球拥有多个品牌,分销商可将其用作替代名称。Honeywell 也可称为以下名称:

  • HONEY
  • HONEYWEL
  • Honeywell Sensing and Productivity Solutions
  • Honeywell Aerospace
  • HONEYWE
  • Honeywell Sensing and Control
  • HON
  • HONEYW
  • Honeywell Microelectronics & Precision Sensors
  • HONEYWELL INTERNATIONAL INC
  • HONEYWELL SENSING & CONTROL
  • HONEYWELL S&C
  • HONEYWELL SENSING
  • HONE
  • HNY
  • HONEYWELL INC
  • HONEYWELL MICROELECTRONICS AND PRECISION SENSORS
  • Honeywell International
  • MICRO SWITCH/HONEYWELL
  • Honeywell Sensing and Control EMEA
  • HNYWEL
  • Honeywell SSEC
  • Honeywell/Microswitch
  • HONEYWELL SENSING & CONTROLS
  • HONEYWELL INTERNATIO