Thermal Shock Min. °C = -40 / Humidity Aging = 85°C @ 1000 h, ±5 % / Passive Aging = 85°C @ 1000h, ±5% / Thermal Shock Max. °C = 85 / Resistance Max. mOhm = 140 / Voltage Rating V = 72 / Wire Diameter mm = 0.81 / Resistance Min. mOhm = 90 / Trip Current A = 3.2 / Operating Temperature Max. °C = 85 / Time to Trip Max. s = 11.4 / Operating Temperature Min. °C = -40