유통업체에서 제공한 Honeywell AWM5102VN에 대한 설명입니다.
Sensor, Airflow; 0 to 10; 60 ms; 10.0 VDC (Typ.); 1 VDC (Typ.); -20 degC; deg
Honeywell AWM5102 VN Mass Airflow Sensor High-Sensitivity Fast Response
HIGH FLOW MASS AIRFLOW SENSOR _NO ROHS
Flow Sensors MASS AIRFLOW 10L/MIN Threaded 1/4 NPT
Flow Sensor Measuring range: 0...10 SLPM Operating temperature: -20...+70 °C Operating voltage: 8...15 VDC
Air Flow Sensor; Port Style:Threaded; External Depth:35mm; External Width:32mm; Length/Height, External:163mm; Mounting Type:Screw; No. of Ports:2; Output Voltage Max:5V; Range:0 to 10 SLPM; Sensor Output:Voltage ;RoHS Compliant: Yes
In-Line Flow MeasurementAWM5000 Series Microbridge Mass Airflow Sensors feature a Venturi type flow housing. They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25" H2
SENSOR, MASS AIR FLOW, 10L/MIN; Pressure Max:50psi; Supply Voltage Range DC:8V to 15V; Port Style:1/4NPT; SVHC:No SVHC (20-Jun-2011); External Depth:35mm; External Length / Height:163mm; External Width:32mm; Fixing Centres LxW:43.2 x 20.3; Flow Rate Max:10l/min; Hysteresis:± 0.5% of reading; Hysteresis:0.5%; Measuring Range:0l/min to 10l/min; Operating Temperature Max:85°C; Operating Temperature Min:-25°C; Output Voltage:5V; Response Time:60ms; Series:AWM5000; Supply Voltage:10VDC; Supply Voltage DC Max:15V
AWM5000 Series airflow sensor, amplified, flow/pressure range: 0 SLPM to 10.0 SLPM; threaded port style, ¼ NPT In-Line Flow Measurement AWM5000 Series Microbridge Mass Airflow Sensors feature a Venturi type flow housing. They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25" H2O. The microbridge chip is in direct contact with the flow stream, greatly reducing error possibilities due to orifice or bypass channel clogging. Rugged, Versatile Package The rugged plastic package has been designed to withstand common mode pressures up to 50 psi, and the small sensing element allows 100 g of shock without compromising performance. The included "AMP" compatible connector provides reliable connection in demanding applications. On-board Signal Conditioning Each AWM5000 sensor contains circuitry which performs amplification, linearization, temperature compensation, and gas calibration. A 1 to 5 Vdc linear output is possible for all listings regardless of flow range (5, 10, 15, or 20 SLPM) or calibration gas (nitrogen, carbon dioxide, nitrous oxide, or argon). All calibration is performed by active laser CAUTION PRODUCT DAMAGE AWM Series Microbridge Mass Airflow Sensors are not designed to sense liquid flow and will be damaged by liquid flow through the sensor. Failure to comply with these instructions could result in product damage.