Air Flow Sensor; Pressure Max:25psi; Por; Pressure Max:25psi; Supply Voltage Range DC:8V to 15V; Flow Measuring Range:0sccm to 1000sccm; SVHC:No SVHC (20-Jun-2011); Connection Size:5.1mm; External Depth:31.5mm; External Length / Height:15.5mm; External Width:54.4mm; Measuring Range:± 1000sccm; Operating Temperature Max:85°C; Operating Temperature Min:-25°C; Output Voltage Max:50mV; Power Consumption:30mW; Response Time:30ms; Sensor Type:Air Flow; Standard:Massflow vs. Differential Pressure; Supply Voltage:10VDC; Supply Voltage DC Max:15V; Supply Voltage Max:15VDC
AWM2000 Series airflow sensor, unamplified (mV), flow/pressure range: ±1000 sccm (1.0 SLPM); straight port style The AWM2000 Series microbridge mass airflow sensor is a passive device comprised of two Wheatstone bridges. The heater control circuit is required for operation per specifications. The sensing bridge supply circuit is also required for operation per specifications. These two circuits are not on board the package and must be supplied in the application. The differential amplifier is a useful interface for the sensing bridge. It can be used to introduce gain and to voltage offsets to the sensor output. CAUTION PRODUCT DAMAGE AWM Series Microbridge Mass Airflow Sensors are not designed to sense liquid flow and will be damaged by liquid flow through the sensor. Failure to comply with these instructions could result in product damage.