Honeywell CSLA2CD

Sensor; Open Loop Current Sensor; LOHET Sensing Mode; 6 to12 VDC
$ 32.885
Obsolete
Richiedi un campioneScheda dati

Prezzo e stock

Schede tecniche e documenti

Scarica le schede tecniche e la documentazione del produttore per Honeywell CSLA2CD.

IHS

Datasheet2 pagine28 anni fa

Honeywell

Newark

Electro Sonic

TME

Cronologia dell'inventario

Trend di 3 mesi:
-36.23%

Modelli CAD

Scarica il simbolo Honeywell CSLA2CD, l'impronta e i modelli STEP 3D dai nostri partner di fiducia.

FONTEeCADmCADFILE
Component Search Engine
SimboloImpronta
3DScarica
Il sito del partner si aprirà in una nuova scheda quando si scaricano i modelli CAD
Scaricando i modelli CAD da Octopart, accetti i nostri Termini e condizioni e l'Informativa sulla privacy.

Supply Chain

Country of OriginMexico
Introduction Date1995-10-01
Lifecycle StatusObsolete (Last Updated: 4 months ago)
LTB Date2022-05-16
LTD Date2022-08-01

Parti correlate

HoneywellCSLA2DE
CURRENT SENSOR, -92A TO 92A, SINK/SOURCE; Available until stocks are exhausted
HoneywellCSLA1CD
Sensor; Open Loop Current Sensor; LOHET Sensing Mode; 8 to 16 VDC
HoneywellCSLA1GD
Open Loop Current Sensor AC/DC Current 9V/12V/15V 3-Pin
SENSOR CURRENT HALL 60A AC/DC
SENSOR CURRENT HALL 60A AC/DC / Current Sensor 60A 1 Channel Hall Effect, Open Loop Bidirectional Module

Descrizioni

Descrizioni di Honeywell CSLA2CD fornite dai suoi distributori.

Sensor; Open Loop Current Sensor; LOHET Sensing Mode; 6 to12 VDC
SENSOR,CURRENT,LINEAR,72A, SINK/SOURCE OUTPUT,THRU HOLE
Current Sensor; Current Range AC:± 72A; Current Range DC:± 72A; Current Rating:20mA; External Depth:10.4mm; Length:34.3mm; Mounting Type:Through Hole; Operational Type:Sink/Source; Output Type:Sink/Source ;RoHS Compliant: Yes
SENSOR, HALL EFFECT; Supply Voltage Range DC:6V to 12V; Sensor Output1:Open Loop; Response Time:3µs; SVHC:No SVHC (20-Jun-2011); Connector Type:3 Pin; Current Consumption:20mA; Current Range AC:0 to 72A; Current Range DC:0 to 72A; Device Type:Open Loop Linear; External Depth:35.6mm; External Length / Height:10.4mm; External Width:34.3mm; Hole Diameter:10.9mm; Operating Temperature Max:85°C; Operating Temperature Min:-25°C; Output Type:Linear; Series:CS; Supply Current:20mA; Supply Voltage DC Max:13.2VDC; Supply Voltage DC Min:5.4VDC; Supply Voltage Range DC:12V; Transducer Function:Linear Current Sensor
CSLA Series inductive analog current sensor, 72 A sensed current, sink or source output, through-hole, operates on AC or DC current, bottom mount CSLA Series inductive analog current sensors incorporate SS490 Series linear Hall-effect sensor ICs. The sensing element is assembled in a printed circuit board mountable housing. This housing is available in four configurations. Normal mounting is with 0.375 inch 4-40 screw and square nut (not provided) inserted in the housing or a 6-20 self-tapping screw. The combination of the sensor, flux collector, and housing comprises the holder assembly. These sensors are ratiometric.

Alias del produttore

Honeywell ha diversi marchi in tutto il mondo che i distributori possono utilizzare come nomi alternativi. Honeywell può anche essere conosciuto con i seguenti nomi:

  • HONEY
  • HONEYWEL
  • Honeywell Sensing and Productivity Solutions
  • Honeywell Aerospace
  • HONEYWE
  • Honeywell Sensing and Control
  • HON
  • HONEYW
  • Honeywell Microelectronics & Precision Sensors
  • HONEYWELL INTERNATIONAL INC
  • HONEYWELL SENSING & CONTROL
  • HONEYWELL S&C
  • HONEYWELL SENSING
  • HONE
  • HNY
  • HONEYWELL INC
  • HONEYWELL MICROELECTRONICS AND PRECISION SENSORS
  • Honeywell International
  • MICRO SWITCH/HONEYWELL
  • Honeywell Sensing and Control EMEA
  • HNYWEL
  • Honeywell SSEC
  • Honeywell/Microswitch
  • HONEYWELL SENSING & CONTROLS
  • HONEYWELL INTERNATIO

Alias del numero di parte

Questa parte può essere conosciuta con i seguenti numeri di parte alternativi:

  • CSL-A2-CD